Subjects: Geosciences >> Space Physics submitted time 2017-03-10
Abstract: Target brightness temperature maps can be used in geostationary interferometric microwave sounder (GIMS) system simulation. System simulation with accurate target brightness temperature maps can evaluate system performance in near real case and thus help adjust design parameters for the sensor before it is finally put into use. In this paper, method of simulating target brightness temperature using Weather Research and Forecasting Model and Radiative Transfer for TOVS (RTTOV) has been discussed. Target brightness temperature simulation results at oxygen absorption band and water-vapor absorption band have been presented. Some preliminary analyses of simulated brightness temperature for GIMS' observation have also been given. �2015 IEEE.
Peer Review Status:Awaiting Review
Subjects: Geosciences >> Space Physics submitted time 2017-03-10
Abstract: Brightness temperature change of observation target in one imaging period will introduce image blur to the retrieved image of geostationary interferometric microwave sounder (GIMS), which uses rotating circular array to realize time-sharing sampling other than snap-shot to reduce system complexity but meanwhile resulting in a relatively long imaging period. In this paper, an interpolation method utilizing time sequence of visibilities collected by time-sharing sampling is presented. The method is verified through a simulation system that simulates GIMS's observation process in viewing a series of near real case brightness temperature maps modeled by FNL/WRF/RTTOV method. Results show that the interpolation method can de-blur the image and reduce imaging error to the degree of snap-shot imaging. �2016 IEEE.
Peer Review Status:Awaiting Review
Subjects: Geosciences >> Space Physics submitted time 2017-03-10
Abstract: Imaging period is an important consideration to geostationary interferometric microwave sounder (GIMS) when mapping fast changing target such as typhoon. GIMS simulation system with near real case observation target can evaluate system performance in different system configurations and thus help determine the optimal imaging period. In this paper, GIMS simulation system using MATLAB and near real case observation modeled by FNL/WRF/RTTOV method has been used to analyze the effect of imaging period on image quality. System simulation results for each frequency channel will be presented and analyses of imaging period's effect on image quality will also be given. �2016 IEEE.
Peer Review Status:Awaiting Review
Subjects: Geosciences >> Space Physics submitted time 2017-03-10
Abstract: In this paper, an SMMW interferometric radiometer concept is demonstrated by a two-element interferometer with dedicated high accuracy SMMW devices. Point-source calibration method is introduced in order to reduce instrument errors. Interference fringes and point target images are presented by this SMMW interferometer. The linear phase error of the interference fringes is less than 2�and the angular resolution is better than 0.57� The measured performance characteristics of the two-element interferometer are consistent with the theoretical analysis. This interferometer demonstrates a new method for passive SMMW remote sensing. �2016, Science Press. All right reserved.
Peer Review Status:Awaiting Review
Subjects: Geosciences >> Space Physics submitted time 2016-05-03
Abstract: Target brightness temperature maps can be used in geostationary interferometric microwave sounder (GIMS) system simulation. System simulation with accurate target brightness temperature maps can evaluate system performance in near real case and thus help adjust design parameters for the sensor before it is finally put into use. In this paper, method of simulating target brightness temperature using Weather Research and Forecasting Model and Radiative Transfer for TOVS (RTTOV) has been discussed. Target brightness temperature simulation results at oxygen absorption band and water-vapor absorption band have been presented. Some preliminary analyses of simulated brightness temperature for GIMS' observation have also been given.
Peer Review Status:Awaiting Review